GOWNS
- ETME 800-SS.L1
- ETME 801-SMS.L1
- ETME 802-LLP.L1
- ETME 810 LLP.L2
- ETME 811-SMS.L2
- ETME 812-SMMS.L2
- ETME 820-LSMS.L3
- ETME 821-LPP.L3
- ETME 823-PLY.L3
- ETME 824-TBND.L3
- ETME 825-LLP.L3
- ETME 830-TBND.L4
- ETME 831-LPP.L4
- ETME 832-TBND.L4
ETME 800-SS.L1 SS Gowns
FABRIC | 40 GSM SS NONWOVEN |
USAGE | Used for MINIMAL risk situations |
PENETRATION | Provides a slight barrier to small amounts of fluid penetration.Single test of water impacting the surface of the gown material is conducted to assess barrier protection performance. |
APPLICABILITY | Basic care, Standard hospital medical unit |
SIZES | S, M, L, XL, XXL |
PACKING | INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE | 40x60x40 cms |
ETME 801-SMS.L1 SS Gowns
FABRIC |
40 GSM SMS NONWOVEN |
USAGE |
Low risk situation to be used,for ,blood draw,suturing in the Intensive Care Unit (ICU), or a pathology lab |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Basic care, Standard hospital medical unit |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 802-LLP.L1 FULL LAMINATED Gowns
TXM 802-LLP.L1 FULL LAMINATED Gowns
FABRIC | 20 GSM PP+15 GSM PE LAMINATED NONWOVEN |
USAGE | Used for MINIMAL risk situations |
PENETRATION | Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY | Basic care, Standard hospital medical unit |
SIZES | S, M, L, XL, XXL |
PACKING | INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE | 40x60x40 cms |
ETME 810 FULL LAMINATED Gowns
FABRIC |
25 GSM PP+ 15 GSM PE LAMINATED NONWOVEN |
USAGE |
Low risk situation to be used,for ,blood draw,suturing in the Intensive Care Unit (ICU), or a pathology lab |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Basic care, Standard hospital medical unit |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 811 FULL ULTRASONIC SMS GOWN
FABRIC |
40 GSM SMS FULL ULTRASONIC GOWN |
USAGE |
Low risk situation to be used,for ,blood draw,suturing in the Intensive Care Unit (ICU), or a pathology lab |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Basic care, Standard hospital medical unit |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 812 SMMS Gowns
FABRIC |
40 GSM SMMS GOWN |
USAGE |
Low risk situation to be used,for ,blood draw,suturing in the Intensive Care Unit (ICU), or a pathology lab |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Basic care, Standard hospital medical unit |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 820 SMS FULL LAMINATED Gowns
FABRIC |
53 GSM SMS EXTERNAL SIDE FULL LAMINATED, INTERNAL SIDE WITH BARRIER Gowns |
USAGE |
Moderate risk,to be used,for arterial blood draw,inserting an Intravenous (IV) Iine,in the Emergency Room,or for trauma cases |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Basic care, Standard hospital medical unit |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 821-LPP.L3 FULL LAMINATED Gowns
FABRIC |
35 GSM PP+ 20 GSM PE LAMINATED NONWOVEN |
USAGE |
Moderate risk,to be used,for arterial blood draw,inserting an Intravenous (IV) Iine,in the Emergency Room,or for trauma cases |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Arterial blood draw, Inserting an IV, Emergency Room, Trauma |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 823-PLY.L3 REUSABLE 100% POLIESTER GOWN
FABRIC |
100% POLIESTER 100GSM FABRIC |
USAGE |
Moderate risk,to be used,for arterial blood draw,inserting an Intravenous (IV) Iine,in the Emergency Room,or for trauma cases |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Arterial blood draw, Inserting an IV, Emergency Room, Trauma |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 824-TBND.L3 THERMABOND + PE LAMINATED 55 GSM Gowns
FABRIC | THERMABOND + PE LAMINATED 55 GSM |
USAGE | Moderate risk,to be used,for arterial blood draw,inserting an Intravenous (IV) Iine,in the Emergency Room,or for trauma cases |
PENETRATION | Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY | Arterial blood draw, Inserting an IV, Emergency Room, Trauma |
SIZES | S, M, L, XL, XXL |
PACKING | INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE | 40x60x40 cms |
ETME 825-LLP.L3 FULL LAMINATED Gowns WITH BARIER
FABRIC |
25 GSM PP+ 15 GSM PE LAMINATED NONWOVEN WITH BARRIER |
USAGE |
Moderate risk,to be used,for arterial blood draw,inserting an Intravenous (IV) Iine,in the Emergency Room,or for trauma cases |
PENETRATION |
Provides a barrier to larger amounts of fluid penetration through splatter and some fluid exposure through soaking Two tests are conducted to test barrier protection performance: 1- Water impacting the surface of the gown material 2- Pressurizing the material |
APPLICABILITY |
Arterial blood draw, Inserting an IV, Emergency Room, Trauma |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 100 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 830-TBND.L4 THERMABOND + PE LAMINATED 55 GSM REINFORCED Gowns
FABRIC |
THERMABOND + PE LAMINATED 55 GSM |
USAGE |
High risk,to be used,for Iong,fluid intense procedures,surgery,when pathogen resistance is needed or infectious diseases are suspected (non-airborne) |
PENETRATION |
May prevent VIRUS penetration for up to 1 hourIn addition to the other tests conducted under levels 1-3, barrier level performance is tested with a simulated blood containing a virus. If no virus is found at the end of the test, the gown passes. |
APPLICABILITY |
Pathogen resistance, Infectious diseases (non-airborne), Large amounts of fluid exposure over long periods |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 70 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 831-LPP.L4 FULL LAMINATED REINFORCED Gowns WITH BARRIER
FABRIC |
25 GSM PP+ 15 GSM PE LAMINATED NONWOVEN + 20 GSM PP BARIER |
USAGE |
High risk,to be used,for Iong,fluid intense procedures,surgery,when pathogen resistance is needed or infectious diseases are suspected (non-airborne) |
PENETRATION |
May prevent VIRUS penetration for up to 1 hourIn addition to the other tests conducted under levels 1-3, barrier level performance is tested with a simulated blood containing a virus. If no virus is found at the end of the test, the gown passes. |
APPLICABILITY |
Pathogen resistance, Infectious diseases (non-airborne), Large amounts of fluid exposure over long periods |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 70 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |
ETME 832-TBND.L4 THERMOBOND+PE LAMINATED 55GSM TEINFORCED GOWN WITH 60 GSM 100% KNITTED COTTON BARIER DISPOSABLE CHEMOTHERAPY GOWN
FABRIC |
THERMOBOND+PE LAMINATED 55GSM TEINFORCED GOWN WITH 60 GSM 100% KNITTED COTTON BARIER |
USAGE |
High risk,to be used,for Iong,fluid intense procedures,surgery,when pathogen resistance is needed or infectious diseases are suspected (non-airborne) |
PENETRATION |
May prevent VIRUS penetration for up to 1 hourIn addition to the other tests conducted under levels 1-3, barrier level performance is tested with a simulated blood containing a virus. If no virus is found at the end of the test, the gown passes. |
APPLICABILITY |
Pathogen resistance, Infectious diseases (non-airborne), Large amounts of fluid exposure over long periods |
SIZES |
S, M, L, XL, XXL |
PACKING |
INDIVIDUAL PACKING, 70 POLY BAG IN A BOX |
BOX SIZE |
40x60x40 cms |